Nanjing Lude Power Equipment Co., Ltd.

服务热线:

18851706160

Banner
新闻详情
Home > news > Content

What are the steps for the weichai generator set wiring?

Edit:Nanjing Lude Power Equipment Co., Ltd.UpDate:2019-04-30

What are the steps for wiring the Weichai generator set ? According to the technical personnel, there are 5 steps in the wiring of the Weichai generator set. Before the wiring, the Weichai generator set is used indoors. It is necessary to guide the exhaust pipe to the outside of the pipe. The diameter of the pipe of the muffler is necessary. The elbow of the road should not exceed 3 to ensure that the smoke is unblocked, and the pipe should be tilted downward by 5-10 degrees to prevent rainwater from being injected; if the exhaust pipe is vertically upwards, it is necessary to install a rain cover.

1. The area around the Weichai generator set should be kept clean to prevent the placement of corrosive gases and vapors that can be acidic or alkaline in the vicinity. Conditional equipment should be equipped with rescue equipment.

2, the equipment address should be well ventilated, the end of the diesel engine generator set should have a satisfactory air inlet, and the end of the diesel generator set should have a good air outlet. The area of the air outlet should be more than 1.5 times the area of the water tank; the air inlet is not smooth or does not meet the requirements, and the air entering the cylinder is less. This will result in insufficient fuel in the cylinder, carbon deposit, and affecting the loading capacity of the diesel generator set. The same exhaust pipe does not meet the requirements, the oxygen content of the air in the equipment room is reduced, and the fuel in the cylinder is not sufficient, and carbon deposition occurs, which affects the loading capacity of the diesel generator set.

3. When concrete is used at the base, the level of the equipment must be measured with a level gauge to fix the unit to the horizontal root. There should be a special shock pad or a foot bolt between the unit and the base.

4. It is necessary to have a solid protective grounding for the unit casing. For generators that require a neutral grounding directly, it is necessary to have a neutral grounding by a professional and equipped with lightning protection equipment. It is forbidden to use the grounding equipment of the mains. The point is directly grounded.

5. The bidirectional switch between the generator and the mains must be very reliable to prevent power transmission. The wiring reliability of the two-way switch needs to be checked by the local power supply.